| Pearce can provide concrete in various slump ranges, depending on strength and workability needs. Ideal slump is in the 4-6" range. The slump test must be performed within 2 1/2 minutes after obtaining the composite sample. |
![]() |
![]() |
![]() |
| Technician begins to fill mold in three equal layers. | Each layer is rodded 25 times to settle the concrete, before the next layer is added. | Full mold is ready to be pulled off to measure slump. |
![]() |
![]() |
![]() |
| Technician must pull mold off within 3-7 seconds for accurate test, per ASTM standards. | Partial mix being revealed by removal of mold. | Full concrete mix now ready for measurement. |
![]() |
||
| This mix shows an ideal slump of around 4.5" measured to the displaced center of the top surface of concrete. |
| This is a general guide meant for informational purposes only, for complete testing procedures refer to ASTM standards or contact Pearce Brothers for more information. |
| Entrained Air Test | Mix Temperature | Molding |